{"product_id":"level-monitor-with-adjustment-rt-814l-html","title":"RT-814L Liquid Level Monitor Relay – 1–100 KΩ Sensitivity, SPDT 12 A \u0026 8-Pin Base","description":"\u003cp\u003eThe RT-814L monitors conductive liquid levels in tanks and pumping units, triggering on minimum or maximum level thresholds. Sensitivity is set via an external potentiometer, allowing the unit to adapt to different liquid conductivity values between 1 KΩ and 100 KΩ.\u003c\/p\u003e\u003cp\u003eIt mounts on an 8-pin lamp base and includes supply voltage and level indicator lamps for at-a-glance status. The single SPDT output relay supports four wiring configurations including two-electrode and three-electrode probe setups.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAdjustable sensitivity from 1 KΩ to 100 KΩ via external potentiometer\u003c\/li\u003e\n\u003cli\u003eSPDT output relay: 12A @ 250V\u003c\/li\u003e\n\u003cli\u003eSupply voltage and level indicator lamps\u003c\/li\u003e\n\u003cli\u003e8-pin lamp base for panel mounting\u003c\/li\u003e\n\u003cli\u003eSupports LC, S, L2C, and L3 wiring functions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct Benefits\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSensitivity adjustment accommodates a wide range of conductive liquids without additional components\u003c\/li\u003e\n\u003cli\u003eMinimum and maximum level monitoring in a single unit protects pumps from running dry or tanks from overflowing\u003c\/li\u003e\n\u003cli\u003e1NO 1NC contacts allow both normally-open and normally-closed circuit control from one relay\u003c\/li\u003e\n\u003cli\u003eIndicator lamps confirm power and level status at a glance, reducing diagnostic time\u003c\/li\u003e\n\u003cli\u003eThree-probe (L3) mode enables independent control of fill and drain circuits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e RT-814L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Conductive liquid level monitor with adjustable sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity Range:\u003c\/strong\u003e 1 KΩ to 100 KΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 12A @ 250V SPDT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Category:\u003c\/strong\u003e AC1 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContacts:\u003c\/strong\u003e 1NO 1NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 230V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase:\u003c\/strong\u003e 8-pin lamp base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Functions:\u003c\/strong\u003e LC (Level Control), S (Sensitivity adjustment), L2C (Two probes + Common), L3 (Three probes)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhy You'll Love It\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eExternal potentiometer allows on-site sensitivity tuning without replacing components\u003c\/li\u003e\n\u003cli\u003e8-pin base makes installation and replacement quick — no wiring changes needed\u003c\/li\u003e\n\u003cli\u003eFour supported wiring functions cover the most common pump and tank control layouts\u003c\/li\u003e\n\u003cli\u003ePackage includes: 1× RT-814L Level Monitor with adjustment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Other","offers":[{"title":"Default Title","offer_id":56578220687742,"sku":"525074","price":26.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0961\/2250\/3550\/files\/15674965918078.webp?v=1779634019","url":"https:\/\/lynk.gr\/en-eu\/products\/level-monitor-with-adjustment-rt-814l-html","provider":"Lynk.gr","version":"1.0","type":"link"}