{"title":"Atman","description":"\u003cp\u003eExplore Atman at Lynk, featuring single-phase isolation transformers in a range of VA ratings. For isolated power supply applications, browse the Atman selection and order online with delivery across Greece.\u003c\/p\u003e","products":[{"product_id":"atman-single-phase-isolation-transformers-ctr-m-s-1000-va-230-230v-html","title":"Atman CTR M\/S 1000VA 230\/230V Single-Phase Isolation Transformer – 3750V AC \u0026 IP20","description":"\u003cp\u003eThe Atman CTR M\/S 1000VA 230\/230V is a single-phase isolation transformer of closed (encapsulated) construction, designed for continuous operation in air under normal cold conditions. It electrically separates primary and secondary circuits with an isolation voltage of 3750V AC and is built to Class I safety standards.\u003c\/p\u003e\u003cp\u003eIts compact footprint — 21.5cm connector-to-connector length, 15cm wide, 13cm tall — suits installation in control panels, industrial enclosures, and workbench setups. The range supports maximum primary voltages up to 1000V AC and secondary voltages up to 500V AC within the product series.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSingle-phase, closed-type isolation transformer\u003c\/li\u003e\n\u003cli\u003eNominal power: 1000VA at 230\/230V\u003c\/li\u003e\n\u003cli\u003eIsolation voltage: 3750V AC (for primary voltage 450V)\u003c\/li\u003e\n\u003cli\u003eClass I construction with insulation classes B, F, and H\u003c\/li\u003e\n\u003cli\u003eIP20 degree of protection\u003c\/li\u003e\n\u003cli\u003eDesigned for continuous operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct Benefits\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGalvanic isolation between primary and secondary prevents ground loops and protects connected equipment\u003c\/li\u003e\n\u003cli\u003e3750V AC isolation voltage provides a robust safety barrier in industrial and laboratory settings\u003c\/li\u003e\n\u003cli\u003eInsulation classes B, F, and H allow use across a range of operating temperature environments\u003c\/li\u003e\n\u003cli\u003eClosed (encapsulated) type keeps internal windings protected from dust and accidental contact\u003c\/li\u003e\n\u003cli\u003eCompact 21.5×15×13cm body fits within standard control panel cutouts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CTR M\/S 1000VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Atman\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Single-phase isolation transformer, closed type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Power:\u003c\/strong\u003e 1000VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Power (series):\u003c\/strong\u003e 3000VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Voltage:\u003c\/strong\u003e 230V (maximum series: 1000V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary Voltage:\u003c\/strong\u003e 230V (maximum series: 500V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 3750V AC (at primary 450V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Class:\u003c\/strong\u003e Class I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Class:\u003c\/strong\u003e B, F, H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Degree:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Continuous, in air, normal cold\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 21.5×15×13cm (connector to connector × W × H)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhy You'll Love It\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e1000VA capacity handles the load of most single-phase workshop and control-circuit applications\u003c\/li\u003e\n\u003cli\u003eClass I construction and IP20 rating meet standard safety requirements for panel installation\u003c\/li\u003e\n\u003cli\u003eClosed enclosure design eliminates the need for additional housing in most installations\u003c\/li\u003e\n\u003cli\u003ePackage includes 1x Atman CTR M\/S 1000VA 230\/230V single-phase isolation transformer\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atman","offers":[{"title":"Default Title","offer_id":56577940226430,"sku":"219033","price":124.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0961\/2250\/3550\/files\/15674844283262.webp?v=1779633531"},{"product_id":"atman-single-phase-isolationtransformers-ctr-m-s-200-va-230-230-html","title":"Atman CTR M\/S 200VA Isolation Transformer 230\/230V – Class B\/F\/H, IP20 \u0026 Continuous","description":"\u003cp\u003eThe Atman CTR M\/S 200VA is a single-phase closed-type isolation transformer designed for service workshops, laboratories, and industrial test benches that need galvanic separation between the mains and a powered device. With a 230V primary feeding a 230V secondary, it provides a one-to-one isolated supply for safer fault diagnosis and operator protection.\u003c\/p\u003e\u003cp\u003eConstruction is closed type with IP20 protection, class B\/F\/H insulation, and a continuous-duty rating, allowing operation in normal cold ambient air. The series limits are documented below for reference.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSingle-phase isolation between mains and load for safer servicing\u003c\/li\u003e\n\u003cli\u003eClosed-type enclosure protects windings and terminals from accidental contact\u003c\/li\u003e\n\u003cli\u003eClass B\/F\/H insulation system supports a wide operating temperature window\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating against finger contact with live parts\u003c\/li\u003e\n\u003cli\u003eContinuous-duty rated for permanent installation in test or workshop benches\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct Benefits\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGalvanic isolation reduces shock risk when probing live circuits during repair\u003c\/li\u003e\n\u003cli\u003eClosed-type design simplifies fixed installation in cabinets and panels\u003c\/li\u003e\n\u003cli\u003eContinuous operation suits long bench sessions without forced cool-down periods\u003c\/li\u003e\n\u003cli\u003eClass I preparation aligns the unit with standard protective earthing practice\u003c\/li\u003e\n\u003cli\u003eSeries withstand voltage of 3750V AC (referenced to a primary of 450V) supports demanding service scenarios\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Single-phase isolation transformer, closed type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Power:\u003c\/strong\u003e 200VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary \/ Secondary Voltage:\u003c\/strong\u003e 230V \/ 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Maximum Power:\u003c\/strong\u003e 3000VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Maximum Primary Voltage:\u003c\/strong\u003e 1000V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Maximum Secondary Voltage:\u003c\/strong\u003e 500V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Withstand Voltage:\u003c\/strong\u003e 3750V AC (referenced to a primary of 450V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class I preparation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Class:\u003c\/strong\u003e B \/ F \/ H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuty:\u003c\/strong\u003e Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Air, normal cold ambient\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 15.5×9.5×8.5cm (terminal-to-terminal × W × H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Atman\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhy You'll Love It\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAtman build quality with closed-type protection for bench or cabinet installation\u003c\/li\u003e\n\u003cli\u003e200VA rating fits low-power service tasks like radios, small motors, and electronics repair\u003c\/li\u003e\n\u003cli\u003eCompact 15.5×9.5×8.5cm footprint sits neatly on a workbench or in a panel\u003c\/li\u003e\n\u003cli\u003ePackage includes 1× Atman CTR M\/S 200VA 230\/230V isolation transformer\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atman","offers":[{"title":"Default Title","offer_id":56579321233790,"sku":"219302","price":46.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0961\/2250\/3550\/files\/15675291238782.webp?v=1779639955"},{"product_id":"atman-single-phase-isolationtransformers-ctr-m-s-300-va-230-230-html","title":"Atman CTR M\/S 300VA Isolation Transformer 230\/230V – Class B\/F\/H, IP20 \u0026 Continuous","description":"\u003cp\u003eThe Atman CTR M\/S 300VA is a single-phase closed-type isolation transformer designed for service workshops, laboratories, and industrial test benches that need galvanic separation between the mains and a powered device. With a 230V primary feeding a 230V secondary, it provides a one-to-one isolated supply for safer fault diagnosis and operator protection.\u003c\/p\u003e\u003cp\u003eConstruction is closed type with IP20 protection, class B\/F\/H insulation, and a continuous-duty rating, allowing operation in normal cold ambient air. The series limits are documented below for reference.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSingle-phase isolation between mains and load for safer servicing\u003c\/li\u003e\n\u003cli\u003eClosed-type enclosure protects windings and terminals from accidental contact\u003c\/li\u003e\n\u003cli\u003eClass B\/F\/H insulation system supports a wide operating temperature window\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating against finger contact with live parts\u003c\/li\u003e\n\u003cli\u003eContinuous-duty rated for permanent installation in test or workshop benches\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct Benefits\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGalvanic isolation reduces shock risk when probing live circuits during repair\u003c\/li\u003e\n\u003cli\u003eClosed-type design simplifies fixed installation in cabinets and panels\u003c\/li\u003e\n\u003cli\u003eContinuous operation suits long bench sessions without forced cool-down periods\u003c\/li\u003e\n\u003cli\u003eClass I preparation aligns the unit with standard protective earthing practice\u003c\/li\u003e\n\u003cli\u003eSeries withstand voltage of 3750V AC (referenced to a primary of 450V) supports demanding service scenarios\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Single-phase isolation transformer, closed type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Power:\u003c\/strong\u003e 300VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary \/ Secondary Voltage:\u003c\/strong\u003e 230V \/ 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Maximum Power:\u003c\/strong\u003e 3000VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Maximum Primary Voltage:\u003c\/strong\u003e 1000V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Maximum Secondary Voltage:\u003c\/strong\u003e 500V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Withstand Voltage:\u003c\/strong\u003e 3750V AC (referenced to a primary of 450V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class I preparation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Class:\u003c\/strong\u003e B \/ F \/ H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuty:\u003c\/strong\u003e Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Air, normal cold ambient\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16×12×10.5cm (terminal-to-terminal × W × H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Atman\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhy You'll Love It\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAtman build quality with closed-type protection for bench or cabinet installation\u003c\/li\u003e\n\u003cli\u003e300VA rating fits medium-load service tasks like amplifiers, motors, and electronics\u003c\/li\u003e\n\u003cli\u003eCompact 16×12×10.5cm footprint sits neatly on a workbench or in a panel\u003c\/li\u003e\n\u003cli\u003ePackage includes 1× Atman CTR M\/S 300VA 230\/230V isolation transformer\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atman","offers":[{"title":"Default Title","offer_id":56579322610046,"sku":"219303","price":57.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0961\/2250\/3550\/files\/15675291304318.webp?v=1779639959"},{"product_id":"atman-single-phase-isolationtransformers-ctr-m-s-400-va-230-230-html","title":"Atman CTR M\/S 400VA Isolation Transformer 230\/230V – Class B\/F\/H, IP20 \u0026 Continuous","description":"\u003cp\u003eThe Atman CTR M\/S 400VA is a single-phase closed-type isolation transformer designed for service workshops, laboratories, and industrial test benches that need galvanic separation between the mains and a powered device. With a 230V primary feeding a 230V secondary, it provides a one-to-one isolated supply for safer fault diagnosis and operator protection.\u003c\/p\u003e\u003cp\u003eConstruction is closed type with IP20 protection, class B\/F\/H insulation, and a continuous-duty rating, allowing operation in normal cold ambient air. The series limits are documented below for reference.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSingle-phase isolation between mains and load for safer servicing\u003c\/li\u003e\n\u003cli\u003eClosed-type enclosure protects windings and terminals from accidental contact\u003c\/li\u003e\n\u003cli\u003eClass B\/F\/H insulation system supports a wide operating temperature window\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating against finger contact with live parts\u003c\/li\u003e\n\u003cli\u003eContinuous-duty rated for permanent installation in test or workshop benches\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct Benefits\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGalvanic isolation reduces shock risk when probing live circuits during repair\u003c\/li\u003e\n\u003cli\u003eClosed-type design simplifies fixed installation in cabinets and panels\u003c\/li\u003e\n\u003cli\u003eContinuous operation suits long bench sessions without forced cool-down periods\u003c\/li\u003e\n\u003cli\u003eClass I preparation aligns the unit with standard protective earthing practice\u003c\/li\u003e\n\u003cli\u003eSeries withstand voltage of 3750V AC (referenced to a primary of 450V) supports demanding service scenarios\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Single-phase isolation transformer, closed type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Power:\u003c\/strong\u003e 400VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary \/ Secondary Voltage:\u003c\/strong\u003e 230V \/ 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Maximum Power:\u003c\/strong\u003e 3000VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Maximum Primary Voltage:\u003c\/strong\u003e 1000V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Maximum Secondary Voltage:\u003c\/strong\u003e 500V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Withstand Voltage:\u003c\/strong\u003e 3750V AC (referenced to a primary of 450V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class I preparation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Class:\u003c\/strong\u003e B \/ F \/ H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuty:\u003c\/strong\u003e Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Air, normal cold ambient\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 17×12×10.5cm (terminal-to-terminal × W × H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Atman\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhy You'll Love It\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAtman build quality with closed-type protection for bench or cabinet installation\u003c\/li\u003e\n\u003cli\u003e400VA rating fits medium-load service tasks like power tools, motors, and lab gear\u003c\/li\u003e\n\u003cli\u003eCompact 17×12×10.5cm footprint sits neatly on a workbench or in a panel\u003c\/li\u003e\n\u003cli\u003ePackage includes 1× Atman CTR M\/S 400VA 230\/230V isolation transformer\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atman","offers":[{"title":"Default Title","offer_id":56579322806654,"sku":"219304","price":60.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0961\/2250\/3550\/files\/15675291337086.webp?v=1779639963"}],"url":"https:\/\/lynk.gr\/en-eu\/collections\/atman.oembed","provider":"Lynk.gr","version":"1.0","type":"link"}